*满足EN55014-1和CISPR 16-1-1的要求 同时测量150 kHz, 500 kHz, 1.4 MHz 和 30 MHz Windonws "Clickware" 软件 软件控制的模块化系统 波形显示 Sensitivity: 20 dBμV (45 dBμV at input of splitter) Attenuation: 0-79 dB variable in 1 dB steps Pulse response, bandwidths etc.: As for CISPR 16 Band B Measurement frequencies: 150 kHz, 500 kHz, 1.4 MHz and 30 MHz Frequency accuracy: ±5% Information displayed: No. of short clicks / No. of long clicks / No. of seconds of continuous interference (resolution 0.1 s). Greater than 2 clicks in 2 s indication / Duration of test (in units of 0.1 minute) / No. of switching operations, Meter Indication Test duration: 0 - 120 minutes in minute steps or continuous Programme controls a heavy duty contactor (15 amp) Manual control of contactor is also possible Construction: Eurocard frame mounted in standard instrument case with integral power supply Power requirements: 120 / 240 V, ±10%, 50 Hz AC, 100 Watt Size (l x W x H, including connectors): 470 x 280 x 290 mm Weight: 10 kg Operating temperature range: 10 to 30°C Computer requirements: 200MHz Pentium or compatible processor Mouse or compatible pointing device 32MB RAM / 10MB Free Hard Disk space Serial port, must be free for connecting to DIA 1512D Windows compatibility: 98, 2000, XP, Vista, 7